Abstract

Introduction and problem statement Given that EUV lithography allows printing smaller Critical Dimension (CD) features, it can result in non-normal distributed CD populations on ADI wafers [Civay SPIE AL 2014], leading to errors in predicted failure rates [Bristol SPIE AL 2017]. As a result, there is a need to quantify the actual behavior of the CD population extremes by means of massive metrology [Dillen EUVL 2018]. Not only allows this to study the CD distribution, we can in parallel also evaluate pattern quality and the failure mechanisms leading to defects. This massive metrology method provides an accurate failure rate based on CD, and enables new possibilities to define a failure rate based on different metrics in a single measurement. Method We analyze the CD uniformity of pillars in polar coordinates using a global waveform based thresholding strategy. In conjunction with this CD information, we also evaluated the print quality of each individual measured feature. Fig 1. In line detected anomalies and failure definitions As we gather this information during the measurement of CD, we can limit the additional measurement overhead to neglectable levels. Application and outlook We will show how we can leverage this to determine a defect based process window and relations of failure mechanisms through process conditions (see figure 2). When we take failures in a CH dataset into account, we illustrate the effect on the shape of a large dataset distribution in figure 3. Fig 2. Defect identification for a through exposure dose experiment of pillars. For each condition >13k pillars where measured. The plot clearly shows an asymmetric behavior due to different failure mechanisms at low and high energy. The 2 vertical lines at relative energies 0.93 and 1.05 times nominal indicate the low defect process window. Fig 3. A distribution of measured regular grid dense CH. The red line is the unfiltered CD data, the blue line is the shape of the distribution after filtering individual CH measurements that have a much lower contrast than expected.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.