Abstract

Marlex (polypropylene) mesh was used to replace the abdominal wall in massive incisional herniation in 50 patients. Seventeen unsuccessful attempts at primary repair had previously been made on nine patients. Patient follow-up ranged from 6 to 120 months (mean = 45 months). There was minor hernia recurrence in four (8 per cent) patients. In each instance it was due to partial detachment of the peripheral fixation of the patch. Complications were: wound infection, four (8 per cent); wound seroma, two (4 per cent); wound haematoma, one (2 per cent); and wound sinus, six (12 per cent). Complications did not necessitate removal of the patch in any case. Inadequate peripheral attachment of the patch has been the only cause of hernia recurrence and should be avoidable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.