Abstract
Reinforced endostapling can prevent postoperative air leakage from surgical stumps. We herein present a 58-year old woman with idiopathic interstitial pneumonia who developed lethal haemothorax after a thoracoscopic lung biopsy with the use of an endostapler preloaded with bioabsorbable tissue reinforcement material. This lethal haemothorax, which occurred on the day after the lung biopsy, required an emergency operation. The bleeding point was an intercostal artery of the inferior chest wall adjacent to the surgical stump. The operative findings suggested that the reinforced material on the surgical stump scratched the chest wall through respiratory movement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.