Abstract

The specially designed ion source of mass spectrometer has been used to measure simultaneously both ions formed by electron impact and by self surface ionization, and from these measurements the work functions and the heats of sublimation of atoms and positive ions of rhenium, tantalum and tungsten have been determined. These values obtained are 5.62±0.08, 7.94±0.20and10.19±0.28eV for rhenium, 5.02±0.11, 8.04±0.12and10.90±0.23eV for tantalum, and 5.04±0.29, 9.28±0.27 and 12.22±0.56eV for tungsten, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.