Abstract

Hepatocellular carcinoma (HCC) is one of the leading causes of cancer-related death, which is demanding powerful diagnosis tools. Although the traditionally used serological biomarker alpha-fetoprotein (AFP) cannot meet the requirement of accuratediagnosis, its isoform alpha-fetoprotein L3 (AFP-L3) ratio in total AFP is emerging as a highly specific alternative.The routine electrophoretic blotting methods for analyzing AFP-L3 isoform ratio are reliable but often lack speediness, sensitivity, or accuracy. Herein, an elemental mass spectrometric strategy was established to simultaneously detect total AFP and AFP-L3 for theaccurate HCC diagnosis. The metal isotopes inside colloidal gold nanoparticle (AuNP) and colloidal silver nanoparticle (AgNP) reporters were used to sensitively detect total AFP and AFP-L3, respectively. AFP-L3 and total AFP were accurately and simultaneously detected with the limits of detection (LODs) of 0.1 ng mL-1 and 0.2 ng mL-1, respectively. The proposed method was successfully validated in a series of human serum samples. The assay procedure was greatly simplified and less time-consuming for the AFP-L3 isoform ratio evaluation, when compared to clinical routine chromatographic/electrophoretic methods. Thanks to the highly multiplex ability of mass spectrometry, the proposed method provides great potential for the analysis of multiple isoforms of various disease biomarkers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call