Abstract

Introduction The measurement of mass flow, a fundamental requirement for any fluid, has been an elusive goal due to the problems of developing a suitable flowmeter. Despite this, the availability of mass flowmeters has increased greatly over the past 25 years. This is partly due to the increasing value of products (Hall 1990), but it is also due to an increasing realisation that volumetric flow measurement is often inappropriate. In addition, the advent of the Coriolis flowmeter has stimulated engineers to find other mass flowmeters. General reviews of mass flowmeters were given by Sproston, Johnson and Pursley (1987), Betts (1990) and Medlock and Furness (1990). Mass flow measurement is sometimes categorised as direct (true) or indirect (inferential). However, it may be useful to allow a few more than two categories. a. True (direct) mass flow measurement by a single instrument is rare. It appears that to achieve it we need to use one of the fundamental acceleration laws. We can do this by creating: • the force (or torque) resulting in a linear (or angular) acceleration (Chapter 19 describes an example) or • the force that produces Coriolis acceleration (Chapter 20). b. Fluid-dependent thermal mass flow measurement uses the temperature rise resulting from heat addition but is affected by other parameters such as the specific heat of the fluid (Chapter 18). c. Multiple differential pressure flowmeters used in a dedicated system (Section 16.2) depend on the nonlinearity of the flowmeter equation. d. Indirect (inferential) mass flow measurement combines volumetric flow rate or momentum flow rate with a density measurement (Section 16.3). (An alternative is to combine volumetric and momentum flow measurements.) e. Multiphase flow measurement almost always requires multiple measurements (Chapter 17). In this edition of the book, I have included a brief survey of mass flowmeters for multiphase flow in Chapter 17. Multiple Differential Pressure Meters Before turning to the one method that is commercially available, for completeness we shall look at two methods that have been suggested but, to my knowledge, have not been used commercially. Twin Venturi System The twin Venturi system depends on the use of two identical Venturi meters (or other differential pressure devices) that are arranged in parallel balanced paths as shown in Figure 16.1.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.