Abstract
In the data processing system for the JT-60 tokamak, a unique mass data acquisition system with fast sampling, a transient mass data storage system (TMDS), has been used since 1988. It is composed of a minicomputer and 61 channels of 4/6 MB memory modules with a sampling rate up to 200 kHz and about 300 MB of data are transferred to a main computer by using a special LAN developed by Fujitsu Ltd. TMDS can handle a large amount of data, but cannot be enlarged in its capability, such as CPU power or the number of channels. To solve the problems of TMDS, a new fast VME data acquisition system (FDS), has been developed. It can acquire 6 MB of data per channel with a sampling rate of 200 kHz or 1 MHz and consists of a workstation with VMEbus memory modules. Up to now there are three FDSs with 24 channels. The minicomputer of TMDS has been replaced with a new system based on the technology of FDS. To cope with mass data transfer to a data server, they are connected with a gigabit ethernet switch.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.