Abstract
To experimentally determine the mass absorption coefficient (μ) of a sp3-carbon (C) atom in the soft X-ray region, soft X-ray absorption spectra (XAS) in the 200-800eV and C K regions of 200-nm-thick self-standing polyethylene (PE) films were measured in the transmission and total electron yield (TEY) modes. PE films were prepared by a spin-coating method. Their experimentally measured thickness and density are 200nm and 0.920g/cm3, respectively. Soft X-ray absorption measurements were performed in beamline BL-6.3.2 at the Advanced Light Source. Although surface oxygen can be slightly observed in the O K and C K regions in TEY-XAS, it cannot be observed in absorbance-XAS. The absorbance-XAS profiles agree well with the calculated profiles, except in the C K threshold. Hence, it can be confirmed that the absorption-XAS measurements are achieved. From the absorbance, μ of sp3-C in PE is 7 × 104 cm2/g near 288eV and 294eV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.