Abstract
For the next years optical lithography stays at 193nm with a numerical aperture of 1.35. Mask design becomes more complex, mask and lithography specifications tighten. The k1 factor comes close to 0.25 which leads to a tremendously increased Mask Error Enhancement Factor (MEEF). This means that CD errors on mask are getting highly amplified on wafer. Process control becomes more important than ever. Accurate process control is a key factor to success to maintain a high yield in chip production. One key parameter to ensure a high and reliable functionality for any integrated circuit is the critical dimension uniformity (CDU). There are different contributors which impact the intra-field CD performance at wafer such as mask CD uniformity, scanner fingerprint, resist process etc. In the present work we focus on improvement of mask CD signature which is one of the main contributors to intra-field CD uniformity. The mask CD uniformity has been measured by WLCD32 which measures the CD based on proven aerial image technology. Based on this CD input the CD uniformity was corrected by CDC200<sup>TM</sup> and afterwards verified by WLCD32 measurement. The CDC200<sup>TM</sup> tool utilizes an ultrafast femto-second laser to write intra-volume shading elements (Shade-In Elements<sup>TM</sup>) inside the bulk material of the mask. By adjusting the density of the shading elements, the light transmission through the mask is locally changed in a manner that improves wafer CDU when the corrected mask is printed. Additionally, the impact of the improved CD uniformity on the lithography process window was investigated. Goal of the work is to establish a process flow for mask CD uniformity improvement based on mask CD metrology by WLCD32 and mask CD uniformity control by CDC200<sup>TM</sup> and to verify its impact on the lithography process window. The proposed process flow will be validated by wafer prints. It was shown that the WLCD32 has an excellent correlation to wafer data and an outstanding CD repeatability. It provides a reliable input for CD uniformity correction and is the tool of choice to verify the CD uniformity improvement after CDC200<sup>TM</sup> treatment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.