Abstract

The marginal fit of Dicor, Cerestore, and porcelain-fused-to-metal crowns was evaluated. Ten premolars free of caries were prepared for each type of restoration and crowns were made. The vertical marginal openings were measured before cementation, after cementation, and after thermocycling. There were statistically significant differences between all three test conditions in each type of crown, between Dicor and porcelain-fused-to-metal crowns after cementation and after thermocycling, and between Cerestore and porcelain-fused-to-metal crowns after thermocycling. All 30 cemented crowns were then embedded in acrylic resin for serial sections for measurement of absolute marginal openings. Statistically significant differences between Dicor and Cerestore crowns and between Cerestore and porcelain-fused-to-metal crowns were found. It was concluded that marginal openings increased after cementation and after thermocycling, and porcelain-fused-to-metal crowns had significantly better marginal fit than that of Dicor and Cerestore crowns.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.