Abstract

Modern welding proceedings can be a beneficial method for repairing marginal adaptation defects in fixed prostheses technology. The aim of the study was to conduct experimental investigations to determine the optimal microplasma welding parameters according to the defect type. Different Ni-Cr alloy cast metal restorations with marginal defects were selected and divided depending on the repair possibility. A microplasma welding device, Welder, was used and as filling material a specific Ni-Cr wire was chosen. The process parameters were determined for each case. Introducing the practice of welding in dental technology requires prior experiments to determine the process parameters for the individual processes and their reproducibility.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.