Abstract

Abstract Calibration chambers are frequently used to verify, adapt, or both verify and adapt empirical relations between different state variables and in situ test results. Virtual calibration chambers (VCC) built with 3D discrete element models may be used to extend and partially substitute costly physical testing series. VCC are used here to explore the mechanics of flat dilatometer penetration and expansion. Results obtained for a simulation of physical tests in Ticino sand are presented. Blade tip resistance during penetration is in good agreement with the experiments. A piston-like design is used for the blade so that larger displacements may be applied than it is possible with a membrane. Initial piston pressures in the expansion curves are very low, strongly affected by the scaled-up grain sizes. Despite that difficulty, expansion curves may be easily interpreted to recover dilatometer moduli ED close to those observed in the physical experiments. Particle-scale examination of the results allows a firmer understanding of the current limitations and future potential of the technique.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.