Abstract

The aim of this study was to analyze the physicochemical and microbiological characteristics of the water used in fish processing and tilapia fillets in slaughterhouses. The study analyzed the processing water from nine slaughterhouses. The water samples for analysis were collected at three points: process water (PW), it is the water used inside the slaughterhouses in direct contact with the fish; clean water entering the purification tank (EPT) and water leaving the purification tank (LPT). The processing waters of the nine tilapia slaughterhouses were analyzed and characterized according to their microbiological and physical-chemical characteristics. The results of microbiological analyzes meet the values indicated by legislation, in most cases. Regarding microbiological data, we can highlight that there was an increase in the total coliforms of the water entering the purification tank to the water leaving the purification tank in five slaughterhouses. Still, there was an increase in the aerobic mesophilic bacteria content observed in the outgoing water in relation to the inlet water of the purification tank in seven slaughterhouses. In relation to the physical chemical analyzes for the process water samples, the results show that the evaluated indices are in accordance with the values indicated by the legislation. The levels of Cd, Mg, Sc and Cd were below that detectable by the analysis in all slaughterhouses. The levels of Al, Sc, As, Rb, Ba, Pb, Mn, As, Se, Rb, Ag, Sb, Ba and Pb were detected only in one or two slaughterhouses. It is concluded that although some abattoirs have water characteristics outside the limits indicated by the legislation, the observed changes were not significant and small adjustments are necessary for the adequacy.

Highlights

  • Among foods of animal origin, fish are present the greatest conditions favorable to deterioration, and, are considered highly perishable

  • The water samples were identified as process water (PW), that is, it is the water used inside the slaughterhouses in direct contact with the fish; clean water entering the purification tank (EPT) and water leaving the purification tank (LPT) (Figure 2)

  • The results presented for total dissolved solids (TDS) in the inlet water of the purification tank and in the water used in the process, showed values lower than

Read more

Summary

Introduction

Among foods of animal origin, fish are present the greatest conditions favorable to deterioration, and, are considered highly perishable. The large number of bacteria found in mucus, gills, and intestines of fish (González, et al, 1999) makes microbial contamination the most important concern in fish processing (Gram & Huss, 1996) These changes in association with intrinsic and extrinsic factors can increase the susceptibility to deterioration of the fish, directly influencing the original organoleptic characteristics of the fish, facilitating the development of food-borne diseases (Huss, 1997; Massaguer, 2005; Jay, 2005, Boari, et al, 2008; Gonçalves, 2011), and compromise the product's useful life (Adebayo-Tayo, et al, 2012). As far as points of interest for microbial control in a slaughterhouse, the water in the purification tank, the processing of the fish at the time of processing and the water used in the ice used for the maintenance of the chilled or frozen fish, are the points that deserve attention and care

Objectives
Methods
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.