Abstract

Microbial monitoring of drinking water is required to guarantee high quality water and to mitigate health hazards. Flow cytometry (FCM) is a fast and robust method that determines bacterial concentrations in liquids. In this study, FCM was applied to monitor the dynamics of the bacterial communities over one year in a full-scale drinking water distribution system (DWDS), following implementation of ultrafiltration (UF) combined with coagulation at the drinking water treatment plant (DWTP). Correlations between the environmental conditions in the DWDS and microbial regrowth were observed, including increases in total cell counts with increasing retention time (correlation coefficient R = 0.89) and increasing water temperature (up to 5.24-fold increase in cell counts during summer). Temporal and spatial biofilm dynamics affecting the water within the DWDS were also observed, such as changes in the percentage of high nucleic acid bacteria with increasing retention time (correlation coefficient R = −0.79). FCM baselines were defined for specific areas in the DWDS to support future management strategies in this DWDS, including a gradual reduction of chloramine.

Highlights

  • Drinking water needs to be safe, esthetically acceptable, and not cause excessive damage to infrastructure

  • The implementation of UF combined with coagulation at the drinking water treatment plant (DWTP) Kvarnagården in Varberg led to a significant change in water quality [2,27]

  • TCC was reduced by a factor of 103 cells/mL and about 50% of natural organic carbon, especially the high molecular weight fraction was removed by direct coagulation over the UF membranes (Figure 1)

Read more

Summary

Introduction

Drinking water needs to be safe, esthetically acceptable, and not cause excessive damage to infrastructure These aspects of water quality are impacted by microorganisms, the majority of which are bacteria that originate from the source water, are shaped by processes in the drinking water treatment plant (DWTP), and are contributed from biofilms in the drinking water distribution system (DWDS) during distribution [1,2,3,4]. The estimated bacterial concentration in most distributed drinking water is between 106 to 108 cells/L [13,14] While these high bacterial counts are generally considered to have no direct impact on public health [9], abrupt changes in bacterial concentrations can indicate failure of disinfection or filtration, or pipe breakage, that could indicate occurrences in the treatment process or external contamination in the DWDS that could indirectly impact the consumer [7]. Requires an understanding of which bacterial counts are expected, with this knowledge generated by comprehensive monitoring of the bacterial community in a DWDS

Objectives
Methods
Results
Conclusion