Abstract
ABSTRACTSlow-release matrix granules were manufactured in the fluidized bed using an aqueous dispersion of quaternary poly(meth)acrylates (Eudragit® RS 30 D) as binder for granulation. A factorial design was carried out to investigate the influence of the following parameters, spraying rate, applied polymer amount, and inlet air temperature, on various granule properties. Prerequisites for a slow release of the model drug theophylline are high spraying rate, high amount of polymer, and low inlet air temperature. No considerable decrease of the drug release rate can be achieved without a subsequent curing of the dry granules. A clear correlation exists between the moisture content of the fluidized bed, indicated by the terminal moisture content (TMC), and the mean dissolution time for 80% of the drug (MDT80).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.