Abstract

Six human donor corneas were studied with the scanning electron microscope to quantify the hazards to the endothelium during the excision of corneoscleral buttons. Although the number studied was small, it was found that: (1) striae were more numerous in the flaccid, very young, donor corneas (under 1 year old) than in the more rigid adult corneas: (2) iridocorneal endothelial touch can result in loss of the posterior membrane and death of the touched endothelial cells. This corroborates the findings of other investigators. Both findings are important, because these conditions reduce the quality of the donor cornea for transplantation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.