Abstract

The study was aimed at esthetic and functional results as well as patient tolerance after reconstruction with reconstruction plate. The follow-up ranged from 1 to 4 years. A retrospective study of 36 patients who had mandibular reconstruction with AO/ASIF stainless steel reconstruction plates after oncologic resection was evaluated. The indications and postoperative outcomes were studied. At the end of study, 24 of 36 patients (67%) still had the plate in place. Around three (8%) plates were fractured. Nine (25%) plates got exposed leading to surgical intervention. Surgical results were satisfying, particularly when looking at delayed healing or long-term tolerance. Esthetic (79% rated results as good or acceptable) and functional results of this reconstruction were satisfying. We conclude by saying that reconstruction plate provides a solution for safe and rapid mandibular reconstruction for patients with poor prognosis or poor condition. This method also preserves the possibility of secondary reconstruction. The reconstruction plate may be a good clinical choice for safe and rapid mandibular reconstruction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.