Abstract

BackgroundWe report a case of a patient who suffered thrombosis of a radial artery-cephalic vein fistula accompanied by aneurysm and a single outflow path of the elbow perforating vein. We performed open surgery combined with Fogarty balloon catheter embolectomy, anastomotic reconstruction and forearm median vein transposition.Case presentationThe patient presented with an arteriovenous fistula (AVF) after haemodialysis 5 years ago. In the process of dialysis, the fistula vein was punctured, resulting in aneurysm, high pressure and difficult haemostasis after needle extraction. AVF occlusion was observed on April 12, 2022. We performed a combined open surgery. First, a Fogarty balloon catheter was used to remove the thrombus, and the anastomosis was then reconstructed to restore AVF fistula patency. Finally, forearm median vein transposition was used to establish dual outflow. Postoperative haemodialysis was possible. There are various methods for removing the thrombus in AVF. Here, we report a case in which we performed open surgery combined with Fogarty balloon catheter embolectomy, anastomotic reconstruction and forearm median vein transposition to ensure fistula patency.ConclusionWe removed a complete reverse ‘Z’-shaped thrombus of the elbow perforating vein in a haemodialysis fistula. This report provides an effective strategy to manage a high-pressure fistula with single outflow of the elbow perforating vein.