Abstract

Two cases of intrastromal corneal ring (Intacs, Addition Technology) implantation to treat post-laser in situ keratomileusis (LASIK) ectasia developed progressive slippage of the flap over the stromal bed, resulting in progressive flattening of the affected meridian. The flattening was thought to have occurred because the poorly healed flap edge could not withstand the change in corneal shape induced by the ring segments. The flap was lifted, debris was removed, and the flap was sutured to the residual stromal bed using interrupted 10-0 nylon sutures passed through two thirds of the cornea. The sutures induced a localized area of scarring that acted as "welding spots" and prevented further flap slippage. Refractive stability after suture removal supports the hypothesis that a sutured flap restores (at least partially) the biomechanical strength of post-LASIK corneas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.