Abstract

Acute hemodynamic compromise due to severe aortic regurgitation remains a difficult problem. The optimal management strategy and timing of surgery continues to evolve as new technologies become available. Here, we report the case of a young woman presenting with severe regurgitation of an aortic homograft who developed precipitous cardiogenic shock and multi-organ dysfunction. Her mortality risk with emergent surgery was prohibitive, and no percutaneous valve-in-valve device was available. We stabilized her condition by placing an Amplatz-type Atrial Septal Defect (ASD) occluder across her aortic valve in conjunction with a percutaneous left ventricular assist device as a bridge to surgical valve replacement. She went on to a successful surgery and recovered well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.