Abstract

IntroductionPosterior cervical foraminotomy and anterior cervical discectomy and fusion (ACDF) are the mainstay treatments for cervical radiculopathy. A recent alternative or adjunct involves the placement of interfacet spacers, which promote indirect decompression by increasing foraminal height. Cervical interfacet spacers have been shown to be safe options for indirect decompression and improve short-term clinical outcomes in patients with cervical spine pathologies. However, no previous data regarding malpositioned spacers and their management have been reported. Given this paucity of data, we aim to present examples of malpositioned interfacet spacers and their management.MethodsThis was a retrospective single-center review.ResultsTwenty-five patients were identified in which interfacet spacers were used at a single level in 19 cases, two levels in five cases, and three levels in one case. The cohort had a mean follow-up of 14.4 months. Among 60 total spacers placed, two required repositioning (3.3%). The first underwent bilateral placement at C4/5 and developed a unilateral deltoid palsy postoperatively. She was taken back to the operating room the same day for implant removal. A second patient underwent removal after a malpositioned implant at C4/5 was identified on an intraoperative CT scan. A third patient had spacers placed at a referring hospital and presented with progressive neck pain and radiculopathy. She underwent successful removal with a resolution of her symptoms.ConclusionsInterfacet spacers represent a novel technique for the treatment of cervical radiculopathy, however, there are limited data on their utilization. We present the first reports of malpositioned spacers and their management. Patients with small facet joints and lateral masses may be at increased risk for malposition, and intraoperative fluoroscopy may not adequately confirm implant placement. Surgeons should use caution when implementing new technology with a low threshold for intraoperative CT to confirm the appropriate placement of these devices.

Highlights

  • Posterior cervical foraminotomy and anterior cervical discectomy and fusion (ACDF) are the mainstay treatments for cervical radiculopathy

  • Twenty-five patients were identified in which interfacet spacers were used at a single level in 19 cases, two levels in five cases, and three levels in one case

  • A second patient underwent removal after a malpositioned implant at C4/5 was identified on an intraoperative CT scan

Read more

Summary

Introduction

Posterior cervical foraminotomy and anterior cervical discectomy and fusion (ACDF) are the mainstay treatments for cervical radiculopathy. A recent alternative or adjunct involves the placement of interfacet spacers, which promote indirect decompression by increasing foraminal height. Cervical interfacet spacers have been shown to be safe options for indirect decompression and improve short-term clinical outcomes in patients with cervical spine pathologies. No previous data regarding malpositioned spacers and their management have been reported. Given this paucity of data, we aim to present examples of malpositioned interfacet spacers and their management

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.