This case series' purpose is to review a referral center's experience with complications from mesh kits. A chart review of 12 patients who presented with complications associated with transvaginal mesh kit procedures was performed. All patients underwent complete surgical removal of the mesh to treat mesh exposure, pain, or vaginal bleeding/discharge followed by an anterior or posterior repair. The mean follow-up time after surgery was 3.4 months. Eight of 12 patients had mesh that had formed a fibrotic band. Six of 12 patients had complete resolution of pain. Of the nine patients with mesh exposure, all required significant resection of the vaginal wall. No further mesh exposure occurred. The use of transvaginal mesh kits may cause previously undescribed complications such as pelvic/vaginal pain or large extrusions requiring complete removal. Removal of all mesh except the arms may cure or significantly improve these problems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.