BackgroundPlacement of pulmonary artery catheters may be associated with a variety of complications. We present a case where a pulmonary artery catheter was accidentally advanced into the left ventricle by perforating the intraventricular septum.Case presentationA 73-year-old woman underwent mitral valve dysfunction. A pulmonary artery catheter could not pass the tricuspid valve under general anesthesia, which was manually advanced via the right ventricle during surgery. After valve replacement, systolic pulmonary artery pressure was higher than radial arterial blood pressure. Transesophageal echocardiography (TEE) revealed the tip of the catheter in the left ventricle. The catheter was withdrawn and then advanced to the pulmonary artery under monitoring of TEE. Transseptal shunt flow gradually decreased and finally disappeared. The surgery was completed without additional procedures.ConclusionsAlthough ventricular septal perforation is rare, it should be recognized as a potential complication of pulmonary artery catheter insertion.