Abstract

We have obtained magnetite mining tailings and used it to fabricate a magnetorheological fluid (MRF). Mineralogical and morphological characteristics were determined using X-ray diffraction (XRD) and energy dispersive spectrometry (EDS), as well as size and geometry for the obtained magnetite. Finally, the fabricated MRF was rheologically characterized in a device attached to a rheometer. The application of a magnetic field of 0.12 Tesla can increase the viscosity of the MRF by more than 400 pct. A structural formation should occur within the fluid by a reordering of particles into magnetic columns, which are perpendicular to the flow direction. These structures give the fluid an increased viscosity. As the magnetic field increases, the structure formed is more resistant, resulting in an increased viscosity. One can appreciate that with a value equal to or less than 0.06 Tesla of applied magnetic field, many viscosity values associated with the work area of the oils can be achieved (0.025 and 0.34 Pa s).