Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background Transvenous lead extraction (TLE) is the mainstay therapy for device-related infections. Though TLE procedures are associated with low complication and high success rates, risk factors for major procedure-related complications remain not well defined. Purpose To evaluate the safety and efficacy of TLE in a large single centre cohort and to identify risk factors for major complications. Methods All consecutive patients undergoing TLE in our department between May 2012 and December 2021 were included in a prospective registry. Our protocol for TLE followed a stepwise approach according to lead dwell time and estimated complexity of the procedure: use of simple traction ± locking stylet (LS) ± mechanical and/or powered sheaths ± snare technique via a femoral or jugular access. Patient characteristics, procedural data and complications were gathered and analysed. Logistic regression analysis was applied to identify risk factors for major procedure related complications. Results A total of 2218 leads (25.7% ICD leads) were targeted for TLE in 1060 patients (67.7 ± 14.8 years; 74% male). The mean lead dwell time was 82 ± 62 months. The leading indication for TLE was cardiac device related infection (CDRI) in 695 patients (65.6%), 373 (35.2%) had systemic and 322 (30.4%) localized infection. Leads were extracted by simple traction in 30%, traction with LS in 3.7%, dilator sheaths with LS in 47.7%, and additional use of powered mechanical sheaths in 14.6%. The snare technique was used in 3.9%, with additional venous entry from femoral in 3.5% and jugular in 1.0% of all targeted leads. TLE was completely successful in 92.6%, partially successful with lead fragments <4cm in 4.2%, and failed in 3.1% of all patients, which translated to a clinical success rate of 96.9%. Twenty-nine patients (2.7%) experienced minor and 18 patients (1.7%) had major procedure-related complications (cardiac tamponade/perforation) including 2 intraprocedural deaths (0.2%). Presence of abandoned leads (HR 8.41, 95% CI 3.21–22.02; p<0.001), lead-years-per-patient (HR 1.063, 95% CI 1.037–1.090; p<0.001), dwelling time of the oldest lead (HR 1.011, 95% CI 1.006–1.016; p<0.001), and a right-sided implantation (HR 2.68, 95% CI 1.05–6.83; p=0.04) were significant predictors of major complications in logistic regression analysis. Conclusion TLE is feasible, effective and safe in our large single centre experience. Overall complication and failure rates are low. Following our TLE protocol, the presence of abandoned leads, a right-sided implantation and dwelling time of the extracted leads were associated with major procedure-related complications.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call