Abstract

This study presents an optimal lighting maintenance plan that takes into account lumen degradation failure. In lighting retrofit projects, retrofitted lights fail over time mainly owing to burnout and lumen degradation failures. These failures result in a reduced illumination level and lower project savings if proper maintenance is not performed. Previous studies developed lighting maintenance plans by modeling lamp population decay due to burnout failure. In this study, we present an optimal lighting maintenance plan based on lumen degradation failure. The lumen degradation failure is modeled based on the statistical properties of degradation rates. By using the Kaplan–Meier method, the formulated lumen degradation failure is used to model the surviving population. The surviving population model is used to design an optimal lighting maintenance plan, which maximizes energy savings and minimizes maintenance costs. The effectiveness of the formulated maintenance plan is demonstrated by an actual residential energy-efficient lighting retrofit project implemented in South Africa. Results show that the proposed maintenance plan is more cost-effective than full maintenance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.