Abstract

Within the framework of the ENFSI Expert Working Group "Firearms," every second year, a proficiency test on the detection and identification of GSR by SEM/EDX is carried out. This proficiency test is a development and extension of the previous proficiency test GSR2001. The test material was again designed by the organization panel and manufactured by an external company for SEM accessories. This time the participating laboratories were requested to determine the total number of PbSbBa containing particles on a test sample following their own laboratory specific methods of automated GSR particle search and detection by SEM/EDX. One synthetic particle sample (SPS) with artificial GSR particles was dispatched to all participants. This paper summarizes the results of the study and assesses the overall performance of the participating laboratories. Furthermore an extended statistical evaluation and a comparison with previous studies was carried out.