Abstract
Inherent concerns for all implant systems exist. These concerns include complex restorative procedures, abutment rotational problems, marginal bone loss, and, in some cases, less than ideal cosmetic results. To overcome or reduce these problems, a new implant has been designed. The implant has been evaluated in this prospective study. Thirty-three new design implants were placed in 11 patients for an average time of 27.25 months. The new implant design proved to be easier to restore, posed no abutment rotational problems, resulted in no marginal bone loss problems (positive bone maintenance), and produced exceptional favorable cosmetic results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.