Abstract

Impaired thresholds at extended high frequencies (EHF) are tightly linked to the prevalence of tinnitus, but little is known about how EHF status relates to tinnitus characteristics. In the present study, 93 individuals with tinnitus underwent standard (from 0.125 to 8 kHz) and EHF (from 10 to 16 kHz) audiometry and indicated their degree of tinnitus distress by completing the tinnitus functional index and their perceived tinnitus loudness by using a numeric rating scale. Partial correlation analyses indicated that the magnitude of EHF loss was significantly associated with degree of auditory related tinnitus distress (r = 0.343, p < 0.001) when controlling for pure tone average at standard frequencies and compensating for multiple testing. It is concluded that EHF status is related specifically to auditory related tinnitus distress, but not to intrusive-, sense of control-, cognitive-, sleep-, relaxation-, quality of life-, emotional-related tinnitus distress, total tinnitus distress, or perceived tinnitus loudness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.