Abstract

The objective of this article is to determine the optimal flow mode in an MR damper to maximize its performance. Flow mode is one of the main design issues in an MR damper, as it determines the velocity profile and the pressure drop across the gap. In this research, two MR dampers were designed and manufactured with two flow modes: valve and mixed. The response of these two dampers was compared experimentally. Additionally, the experimental tests were correlated by theoretical results that were obtained considering the rheological behaviour of the MR fluid, the shear stress distribution in the gap, and the damper movement. Interestingly, the obtained results suggest that flow mode is not a significant parameter for determining the behaviour of a MR damper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.