Abstract

The aim of epilepsy surgery in patients with focal, pharmacoresistant epilepsies is to remove the complete epileptogenic zone to achieve long-term seizure freedom. In addition to a spectrum of diagnostic methods, magnetoencephalography focus localization is used for planning of epilepsy surgery. We present results from a retrospective observational cohort study of 1000 patients, evaluated using magnetoencephalography at the University Hospital Erlangen over the time span of 28 years. One thousand consecutive cases were included in the study, evaluated at the University Hospital Erlangen between 1990 and 2018. All patients underwent magnetoencephalography as part of clinical workup for epilepsy surgery. Of these, 405 underwent epilepsy surgery after magnetoencephalography, with postsurgical follow-ups of up to 20 years. Sensitivity for interictal epileptic activity was evaluated, in addition to concordance of localization with the consensus of presurgical workup on a lobar level. We evaluate magnetoencephalography characteristics of patients who underwent epilepsy surgery versus patients who did not proceed to surgery. In operated patients, resection of magnetoencephalography localizations were related to postsurgical seizure outcomes, including long-term results after several years. In comparison, association of lesionectomy with seizure outcomes was analysed. Measures of diagnostic accuracy were calculated for magnetoencephalography resection and lesionectomy. Sensitivity for interictal epileptic activity was 72% with significant differences between temporal and extra-temporal lobe epilepsy. Magnetoencephalography was concordant with the presurgical consensus in 51% and showed additional or more focal involvement in an additional 32%. Patients who proceeded to surgery showed a significantly higher percentage of monofocal magnetoencephalography results. Complete magnetoencephalography resection was associated with significantly higher chances to achieve seizure freedom in the short and long-term. Diagnostic accuracy was significant in temporal and extra-temporal lobe cases, but was significantly higher in extra-temporal lobe epilepsy (diagnostic odds ratios of 4.4 and 41.6). Odds ratios were also higher in non-lesional versus lesional cases (42.0 versus 6.2). The results show that magnetoencephalography provides non-redundant information, which significantly contributes to patient selection, focus localization and ultimately long-term seizure freedom after epilepsy surgery. Specifically in extra-temporal lobe epilepsy and non-lesional cases, magnetoencephalography provides excellent accuracy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.