We have developed a new magneto-optical measurement system using a rotational cavity system equipped with a millimeter vector network analyzer and a 14 T solenoid type super conducting magnet. The measurement can be performed in the transmission configuration down to 1.6 K. The results of the precise angular dependence measurement of quasi-one-dimensional organic conductor (DMET)2I3 using the new system are shown, and its Fermi surface will be discussed in connection with the previous reports.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Infrared and Millimeter Waves
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.