Abstract

In practical applications, BSCCO/Ag tapes are exposed to external AC magnetic field and fed with an AC transport current. The total AC loss can be separated in two contributions: first, the transport current loss influenced by an external AC magnetic field, and second, the magnetisation loss that depends on the transport current running through the conductor. In this paper the total AC loss is considered and the role of the electric and magnetic components is compared. This comparison is made with an available analytical model for the AC loss in an infinite slab and verified experimentally for a BSCCO/Ag tape conductor. For small transport currents the magnetisation loss dominates the total loss. When the current increases, a field dependent crossover occurs, after which the transport current loss also plays a role. Qualitatively the measurements can be described well in terms of the critical state model. For magnetic field parallel to the wide side of the conductor the CSM for an infinite slab describes the measurements also quantitatively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.