Abstract

Magnetic sensorless control experiments of the plasma horizontal position have been carried out in the superconducting tokamak HT-7. Previously the horizontal position was calculated from the vertical field coil current and voltage without using signals of magnetic sensors like magnetic coils and flux loops placed near the plasma. The calculations are made focusing on the ripple frequency component of the power supply with thyristor and directly from them without time integration. There is no drift problem of integrator of magnetic sensors. Two kinds of experiments were carried out, to keep the position constant and swing the position in a triangular waveform.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call