Abstract

Power system dynamic performance is very much affected by synchronous machines model. In particular, magnetic saturation gives substantial effects and its physical interpretation is usually complicated and difficult. Therefore saturation phenomenon has been studied long in the field of electric power system and machine analysis. Recently numerical magnetic field analysis such as FEM are widely used to consider this effect, but it needs heavy computation of large dimension matrix and necessary computing time is too long for us to apply it to multi machine power system analysis. From the viewpoint of power system analysis more sophisticated and compact model is highly required. This paper proposes a new method to take into account effects of magnetic saturation in a synchronous machine with a cylindrical rotor. It gives the additional calculation which represent the effects of magnetic saturation using so called perturbation series method applied to the nonlinearity in the magnetic permiability. Using the model generator it is confirmed that the proposed method shows good accuracy even in heavily loaded condition, in which linear analysis failed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.