Abstract

The 3D-REAL-IR MRI sequence allows for an in vivo visualization of endolymphatic hydrops. Qualitative assessment methods of the severity of vestibular and cochlear hydrops are the most commonly used. A quantitative volumetric measurement of vestibular EH in patients with definite unilateral Ménière's disease using the 3D-REAL-IR sequence and the calculation of the endolymphatic ratio (ELR) was intended. Volumetric calculations of the vestibules, vestibular endolymph and vestibular ELR are performed in 96 patients with unilateral Ménière's disease and correlated with classic qualitative grading scales. Quantitative volumetric measurement of vestibular hydrops using the 3D-REAL-IR sequence is feasible and reproducible in daily clinical practice. Vestibular ELR values exceeding 60% defined radiologically significant vestibular hydrops, while values below 30% defined radiologically non-significant vestibular hydrops.