Abstract
BackgroundLymphatic complications are common in patients with Fontan circulation. Three-dimensional balanced steady-state free precession (3D bSSFP) angiography by cardiovascular magnetic resonance (CMR) is widely used for cardiovascular anatomical assessment. We sought to determine the frequency of thoracic duct (TD) visualization using 3D bSSFP images and assess whether TD characteristics are associated with clinical outcomes. MethodsThis was a retrospective, single-center study of patients with Fontan circulation who underwent CMR. Frequency matching of age at CMR was used to construct a comparison group of patients with repaired tetralogy of Fallot (rTOF). TD characteristics included maximum diameter and a qualitative assessment of tortuosity. Clinical outcomes included protein-losing enteropathy (PLE), plastic bronchitis, listing for heart transplantation, and death. A composite outcome was defined as presence of any of these events. ResultsThe study included 189 Fontan patients (median age 16.1 years, IQR 11.0–23.2 years) and 36 rTOF patients (median age 15.7 years, IQR 11.1–23.7 years). The TD diameter was larger (median 2.50 vs. 1.95 mm, p = 0.002) and more often well visualized (65% vs. 22%, p < 0.001) in Fontan patients vs. rTOF patients. TD dimension increased mildly with age in Fontan patients, R = 0.19, p = 0.01. In Fontan patients, the TD diameter was larger in those with PLE vs. without PLE (age-adjusted mean 4.11 vs. 2.72, p = 0.005), and was more tortuous in those with NYHA class ≥ II vs. class I (moderate or greater tortuosity 75% vs. 28.5%, p = 0.02). Larger TD diameter was associated with a lower ventricular ejection fraction that was independent of age (partial correlation = − 0.22, p = 0.02). More tortuous TDs had a higher end-systolic volume (mean 70.0 mL/m2 vs. 57.3 mL/m2, p = 0.03), lower creatinine (mean 0.61 mg/dL vs. 0.70 mg/dL, p = 0.04), and a higher absolute lymphocyte count (mean 1.80 K cells/µL vs. 0.76 K cells/µL, p = 0.003). The composite outcome was present in 6% of Fontan patients and was not associated with TD diameter (p = 0.50) or tortuosity (p = 0.09). ConclusionsThe TD is well visualized in two-thirds of patients with Fontan circulation on 3D-bSSFP images. Larger TD diameter is associated with PLE and increased TD tortuosity is associated with an NYHA class ≥ II.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.