Abstract

BackgroundThis study examined the structural outcomes for joints of boys with severe hemophilia A receiving frequency/dose‐escalated primary prophylaxis using magnetic resonance imaging (MRI), and the importance of interval MRI changes. MethodsForty‐six subjects (27 with interval studies) were evaluated by radiographs (X‐rays) and mid‐ and end‐of‐study MRIs (using the International Prophylaxis Study Group scale), as part of the Canadian Hemophilia Prophylaxis Study. The primary outcome was the presence of MRI osteochondral findings. ResultsThe median (range) time on study at the end‐of‐study MRI examination was 9.6 (4.8–16.0) years, during which 18 of 46 subjects (39%) had osteochondral changes in at least one joint. An interval change in MRI score of at least 1 point was observed in 44% of joints (43 ankles, 21 elbows, 4 knees); at least one joint showed this change in all 27 subjects. Self‐reported interval hemarthrosis was associated with a higher likelihood of interval osteochondral change (odds ratio [OR], 1.49; 95% confidence interval [CI] = 1.08–2.06). Presence of synovial hypertrophy or hemosiderin on interval MRIs was associated with an OR of 4.71 (95% CI, 1.92–11.57) and 5.25 (95% CI, 2.05–13.40) of later osteochondral changes on MRI. DiscussionMRI changes were seen in 39% of subjects. Interval index joint bleeding was associated with an increased risk of later MRI changes, and earlier soft‐tissue changes were associated with subsequent osteochondral changes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call