Abstract

PurposeThis prospective registry study evaluated the feasibility of stereotactic magnetic resonance imaging (MRI)–guided radiation therapy for the local treatment of isolated prostate cancer recurrence within the gland or prostate bed after primary radiation therapy. Methods and MaterialsPatients with isolated recurrence without any regional or distant extension after treatment by external radiation therapy of the prostate gland/bed or by prostate brachytherapy were included. A 173-second Fast Imaging with Steady state Precession (TrueFISP) sequence was used for MRI simulation, and the gross tumor volume was delineated using multimodal images. The initial treatment plan varied from 27.5 Gy in 5 fractions to 38.7 Gy in 9 fractions and was adapted at each session, if necessary. The primary endpoint was acute toxicities (according to the Common Terminology Criteria for Adverse Events v5.0 criteria). Secondary endpoints were the effects of the adaptive treatment on target volume coverage, late toxicities, and oncologic events. ResultsTwenty patients were included. After a minimum follow-up of 6 months, grade 2 dysuria (from grade 1 at baseline; n = 1), grade 2 polyuria (n = 1), grade 1 urinary incontinence (n = 1), grade 1 urinary pain (n = 2), and grade 1 diarrhea (n = 1) were reported.All initial treatment plans met the tumor coverage objectives, with a mean 95% planning target volume value of 95.7%. No plan exceeded the bladder and rectum dose constraints, but 8 exceeded the urethra dose constraints because of urethra proximity to the planning target volume. The initial plan was adapted in 7 patients (35%). The tumor coverage improved by 3.7% compared with the predicted plan (P = .0001) without increase in the dose to organs at risk. The biochemical control rate for the whole cohort was 75% (15/20 patients) including the 4 patients who received androgen-deprivation therapy. ConclusionsMRI-guided reirradiation for isolated recurrence within the prostate or in the prostate bed appears to be safe with excellent dosimetric results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.