Abstract

A novel response function calibration technique has been developed to account for time-dependent nonaxisymmetric eddy currents near magnetic sensors in toroidal magnetic confinement devices. The response function technique provides a means to cross calibrate against all available external field coil systems to calculate the absolute sensitivity of each magnetic field sensor, even when induced eddy currents are present in the vacuum vessel wall. The response function information derived in the calibration process can be used in equilibrium reconstructions to separate plasma signals from signals due to externally produced eddy currents at magnetic field sensor locations, without invoking localized wall current distribution details. The response function technique was used for the first ever equilibrium reconstructions of spherical torus plasmas, when applied to the Current Drive Experiment-Upgrade (CDX-U) device. In conjunction with the equilibrium and stability code (ESC), equilibria were obtained for recent CDX-U experiments with lithium plasma-facing components. A description of the CDX-U magnetic sensor configuration and the response function calibration technique will be presented along with examples of resulting plasma equilibrium for CDX-U lithium wall operations.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call