Abstract
We discuss initial magnetic field strength measurements made around radiofrequency (RF) induction heaters. These measurements were made with a monitor developed for the National Institute for Occupational Safety and Health (NIOSH) by the National Bureau of Standards (NBS). The monitor has a dynamic range of .01 to 10,000 A2/m2, a frequency range of 300 kHz to 100 MHz, an isotropic response (+/- .3 dB) with three mutally orthogonal loop antennas that have the ability to measure and display each of three orthogonal magnetic field components, a high probe burnout protection level of 20,000 A2/m2, and an accuracy of +/- 1.0 dB at 13 calibration frequencies. The portable survey monitor was used to measure the magnetic field strengths in the vicinity of 16 RF induction heaters. Typically these induction heaters are operated continuously for several hours. The maximum field strengths (without duty factor correction) ranged from 15 to 4,500 A2/m2 and were measured 5 to 51 cm from the loop applicators of the induction heaters. At locations commonly occupied by workers (ie, approximately 30 to 76 cm from heaters), the fields ranged from .01 to 300 A2/m2 (without duty factor correction).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.