Abstract

Summary form only as given. This paper discusses the effect of external low frequency magnetic field interference on cathode ray tube (CRT) computer monitors. The paper describes a new test facility and presents a quantitative measuring method which has been developed to characterize the field effects. A total of monitors from major manufacturers were tested. It was found that larger monitors are more sensitive and that the relationship between the magnitude of jitter and the magnetic flux density is linear and independent of the refresh rate and the frequency of the interfering magnetic field. The monitors are most sensitive to magnetic fields parallel to the screen. Monitor sensitivity is specified and presented for the tested monitors. A statistical survey was carried out to determine the human perceptibility level of jitter. It was found that 12 mG may cause detectable jitter for the common 14 monitor. This value drops to around 7 mG for a 21 monitor.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.