Abstract

If the major axes of the helical and vertical field coils of a torsatron plasma confinement device are not aligned to within ∼1% of their major radii, the resulting error field can break up closed magnetic flux surfaces and reduce the effective plasma confinement volume. A novel technique for accurately locating the magnetic symmetry axes of torsatron helical and vertical coil sets to within ∼1 mm using magnetic field measurements near the device major axis (i.e., away from the confinement volume) is described and applied to the URAGAN-3 torsatron. The axis of the vertical field coil set was found to be shifted by ∼1 cm relative to the axis of the helical coil set; this shift could account for the reduced confinement volume observed in previous experiments. The magnetic measurements were repeated after coil repositioning to verify correct alignment.