This contribution is focused on the magnetic signatures of type I ELM filaments. On JET a limited number of high time resolution magnetic coils were used to derive essential ELM filament parameters. The method uses forward modelling and simultaneous fitting of magnetic pickup coil signals to a simple model, motivated by observations. A new diagnostic in the form of a reciprocating probe with three magnetic pickup loops was developed for ASDEX Upgrade (AUG). Measurements during the passage of type-I ELM filaments determine the filaments to be in the scrape off layer (SOL) and to carry currents up to 1.5kA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.