In this report, we present our recent progress in the design and high-power testing of the 2nd harmonic cavity for the China Spallation Neutron Source upgrade project. To achieve optimal performance, high-performance magnetic alloy (MA) cores with dimensions of Φ850mm × Φ316mm × 25mm were meticulously developed and fabricated to serve as the load material for the radio-frequency (RF) cavity. Through rigorous testing, we were able to achieve a remarkable cavity accelerating gradient of over 40 kV/m under 15% duty cycle. To ensure optimal cooling efficiency, we conducted a comprehensive fluid dynamics simulation analysis and verified our results through experiments. Finally, to assess the long-term stability and performance of the cavity, we conducted a series of extended operation tests. These experiments successfully confirmed the high-performance capabilities and exceptional stability of the 2nd harmonic cavity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.