Abstract

Coils employed in the magnets of the PHENIX Detector, presently under construction for RHIC (Relativistic Heavy Ion Collider) at the Brookhaven National Laboratory, are massive (weight /spl sim/8000 kG each). For that reason we subdivided them into a series of manageable subcoils that we will subsequently bolt together. Electrical terminals attached to the subcoils conductors are rigidly embedded and precisely located during vacuum impregnation. However, we anticipate some misalignment and nonuniform gaping to occur between terminals at assembly. We have elected to use electrical gaskets of high compliance and ampacity between the bolted terminals to enhance the current carrying capability of the electrical joints. This paper describes the material candidates selected, the tests performed, and the relative ranking of the materials tested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.