Abstract
BackgroundThere is a paucity of research investigating the application of machine learning techniques for distinguishing between lipid-poor adrenal adenoma (LPA) and subclinical pheochromocytoma (sPHEO) based on radiomic features extracted from non-contrast and dynamic contrast-enhanced computed tomography (CT) scans of the abdomen.MethodsWe conducted a retrospective analysis of multiphase spiral CT scans, including non-contrast, arterial, venous, and delayed phases, as well as thin- and thick-thickness images from 134 patients with surgically and pathologically confirmed. A total of 52 patients with LPA and 44 patients with sPHEO were randomly assigned to training/testing sets in a 7:3 ratio. Additionally, a validation set was comprised of 22 LPA cases and 16 sPHEO cases from two other hospitals. We used 3D Slicer and PyRadiomics to segment tumors and extract radiomic features, respectively. We then applied T-test and least absolute shrinkage and selection operator (LASSO) to select features. Six binary classifiers, including K-nearest neighbor (KNN), logistic regression (LR), decision tree (DT), random forest (RF), support vector machine (SVM), and multi-layer perceptron (MLP), were employed to differentiate LPA from sPHEO. Receiver operating characteristic (ROC) curves and area under the curve (AUC) values were compared using DeLong’s method.ResultsAll six classifiers showed good diagnostic performance for each phase and slice thickness, as well as for the entire CT data, with AUC values ranging from 0.706 to 1. Non-contrast CT densities of LPA were significantly lower than those of sPHEO (P < 0.001). However, using the optimal threshold for non-contrast CT density, sensitivity was only 0.743, specificity 0.744, and AUC 0.828. Delayed phase CT density yielded a sensitivity of 0.971, specificity of 0.641, and AUC of 0.814. In radiomics, AUC values for the testing set using non-contrast CT images were: KNN 0.919, LR 0.979, DT 0.835, RF 0.967, SVM 0.979, and MLP 0.981. In the validation set, AUC values were: KNN 0.891, LR 0.974, DT 0.891, RF 0.964, SVM 0.949, and MLP 0.979.ConclusionsThe machine learning model based on CT radiomics can accurately differentiate LPA from sPHEO, even using non-contrast CT data alone, making contrast-enhanced CT unnecessary for diagnosing LPA and sPHEO.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.