Abstract

Inhalation delivery is a promising route for drug administration. The particles of drug aerosol must have a diameter between 1 and 3 μm. The use of microspherical particles based on protein matrix allows for enhanced bioavailability of poorly water-soluble drugs and improved biocompatibility. In the present work, spray drying method was employed for the preparation of the microspherical particles of lysozyme with a model drug compound phenacetin. The average aerodynamic radius of the prepared particle is 1 μm. We show that the spray drying regime produces microparticles with low residual solvent content. The release time of phenacetin from the microspherical particles is much lower than that of the pure drug. These results allow developing a strategy for the production of the protein matrix-based systems for the inhalation delivery of poorly water-soluble drugs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.