Abstract

An efficient freeze‐dry cycle was developed for a high concentration monoclonal antibody formulation lacking a crystalline bulking agent. The formulation, at multiple protein concentrations, was characterized using differential scanning calorimetry (DSC) and freeze‐dry microscopy. At low protein concentrations the glass transition temperature of the maximally freeze‐concentrated solution (Tg′) determined by DSC was similar to the collapse temperature determined by freeze‐dry microscopy. However, at higher protein concentrations, the difference between collapse temperature and Tg′ became progressively larger. The difference between the onset temperature for collapse and the complete collapse temperature also became progressively larger as protein concentration increased. JMP® Design of Experiment studies were used to assess the effect of freezing rate, primary drying shelf temperature, and chamber pressure on primary drying product temperature, length of primary drying, and product quality attributes. Primary drying was shortened significantly by adjusting to conditions where the product temperature substantially exceeded Tg′ without any apparent detrimental effect to the product.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.