Abstract

BackgroundChylothorax is a condition that can be challenging to diagnose due to its nonspecific clinical presentation. Several biochemical parameters of chylous pleural effusion have been identified as important indicators for the diagnosis of chylothorax. Lymphoscintigraphy is utilized to assess chylothorax and determine the location of chyle leakage. The present study aimed to evaluate the correlation between the biochemical parameters of chylous pleural effusion and 99mTc-dextran (99mTc-DX) lymphoscintigraphy in diagnosing chylothorax.Material and methodsA total of 120 patients were enrolled in the study, 83 of the patients with unilateral chylothorax, and 37 with bilateral chylothorax. All patients underwent both 99mTc-DX lymphoscintigraphy and pleural effusion laboratory analysis. The 99mTc-DX lymphoscintigraphy images were categorized as positive or negative groups based on the presence or absence of abnormal radioactive tracer accumulation in the thorax, respectively. The biochemical parameters of the two groups were subsequently compared.ResultsAmong these patients, 101 (84.17%) had exudative effusions, while 19 (15.83%) had transudative effusions, as determined by the levels of pleural effusion protein, lactate dehydrogenase and cholesterol. Abnormal tracer accumulation in thorax was observed in 82 patients (68.33%). Our findings indicated that lymphoscintigraphy results were not associated with exudative and transudative chylothorax (P = 0.597). The lymphoscintigraphy positive group displayed significantly higher levels of pleural effusion triglyceride and pleural effusion triglyceride/serum triglyceride ratio in all biochemical parameters, compared to the negative group (P = 0.000 and P = 0.005). We identified cutoff values of 2.870 mmol/L for pleural effusion triglycerides and 4.625 for pleural effusion triglyceride/serum triglyceride ratio, respectively, which can facilitate differentiating the positive and negative cases on lymphoscintigraphy.ConclusionLymphoscintigraphy technique is a dependable diagnostic tool for the qualitative assessment of chylous pleural effusion. Higher pleural effusion triglyceride level and pleural effusion triglyceride/serum triglyceride ratio indicate a positive result in patients with chylothorax on lymphoscintigraphy, with the cutoff values of 2.870 mmol/L and 4.625 aiding in the diagnosis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.